BOSEAN – BH-90A
Description
Gas Detected:
combustible gas (CH4,C3H8,H2) and toxic gas, oxygen, Other rare toxic gas like ammonia, NO, PH3, NH3, NO2, HCN, SO2 etc also available, can be specified by the Customer in advance.
*Advanced MCU control with low power consumption;
*Adjustable low and high alarm level;
*Adjustable calibrating level;
*High concentration protection for combustible gas;
*Self test for the combustible gas sensor;
*Low battery indication;
*Self-adjustment function
*Visual and audible alarm with vibration;
*Advanced self-examination and self-renovation function
*Password management to avoid wrong operation;
*Explosive proof housing.
Accuracy: ≦ 5% F.S.
Response time: T<30s
Indication: LCD indicates the time and state Indication of alarm, fault and low voltage with LED, sound, vibration
Operating Environment:
Operating temperature -40℃~70℃ (for combustible gas)
Operating temperature: -20℃~50℃ (for toxic gas)
Humidity:<95%RH non-condensing
Operating voltage: DC3.7V Li battery 1500mAh
Working time: ≧8h continuously
Charging time: 4h~6h
Sensor life: 2 years
Weight: about 130g (including battery but without accessories)
Explosion proof: Ex ib llB T3 Gb
Dimension: 100mm×60mm×30mm